6. The HD-SDI jacks will be numbered 23 and 24.
7. The CATV jacks will be numbered 23 and 24.
8. The plate will be located in the stage right rack.
f. Rack and Power
i. The rack shall be a Middle Atlantic 44sp ERK-44-25 rack.
ii. The AV contractor shall provide appropriate blank panels to fill the front of
the rack as indicated on the rack elevation drawings.
iii. SurgeX SEQ: The SEQ shall be a two-rack-space unit in a magnetic
shielding steel enclosure. It shall operate from 120 volts AC and have a 9-
foot, grounded, 3-wire #12 line cord. There shall be 12 grounded AC
receptacles in three banks of four on the rear panel, each bank sequenced
from the previous bank by an adjustable 0 - 40 second delay, and two
receptacles always on. There shall be a back-lit LCD display that shows unit
status and AC line voltage, and two screwdriver adjustments to program the
unit. Overall dimensions shall be 3.5” H x 19” W x 10.5” D. Weight shall be
16 pounds.
The SEQ shall have a load rating of 20 amps at 120 volts, a self-test circuit
with visual indicator and provide EMI/RFI filtering, inrush current
elimination and catastrophic over/under-voltage shutdown. It shall meet
Federal Grade A, Class 1, Mode 1 guidelines for powerline surge
suppressors and withstand at least 1000 occurrences of surge pulse voltages
up to 6000 volts.
The SEQ will be controlled by the Crestron Control System
iv. One Middle Atlantic PDC-915R-6 power strip will be connected to a 20A
circuit will be controlled by the Crestron Control System.
g. Video Add/Alternates
i. Option 1: Sharp PN-E601 monitors will replace the PN-E521 monitors, qty
16. The input card will change to a PN-ZB02, qty 16. The mounts and
cables will change quantity from 25 to 16.
3. Network Equipment
a. Two HP V1920-24G switches will provide network connectivity for all AV
equipment and jacks located in the Auditorium. One will be located in the Booth
rack and one in the Stage rack.
b. A Linksys SD2005 five port switch will provide network connectivity in the sound
board rack.
4. Control System
a. A control system will be installed to offer a graphical user interface on two touch
panels that provides control of the audio, video and lighting systems.
i. The hardware shall consist of a central processor, a table top 9” touchpanel
for the booth and a 6” wireless touchpanel for the podium. The 6” panel
shall have a rack mounted dock for the stage rack and a table top dock for
Kommentare zu diesen Handbüchern